Intelligent Electrical Contracting System

Integrated power distribution, emergency supply, metering and EMS/BMS supervision.

Scorpions Services delivers an end-to-end electrical contracting system that combines reliable normal power, resilient emergency power, safe distribution, granular metering and centralized operational intelligence. The design links the utility supply, MV intake, transformers, MDBs, SMDBs, ESMDB/EMDB panels, final DBs, generators, ATS/AMF, UPS systems, KWH/power-quality meters, MCC/VFD panels and renewable sources into one coordinated installation.

The EMS/BMS layer gives real-time visibility, alarms, trends, demand analysis and reporting, while certified electrical protection stays local to the switchgear and equipment.

Design • Supply • Installation • Testing • Commissioning • Handover • Maintenance

Power

Grid + Generator
ATS, UPS, MDB/SMDB, optional solar

Distribution

Essential + Normal
Panels, cables and loads

Intelligence

EMS / BMS
Alarms, trends, reports

Delivery

End-to-end scope
Design to after-sales

Key Outcomes

  • Safe, selective distribution from source to final circuit
  • Automatic restoration of essential services after utility failure
  • No-break continuity for critical loads through UPS
  • Metering by source, building, floor, tenant, department or major load
  • Fast fault response using alarm, event and breaker/source-status visualization
  • Peak-demand, power-factor, load-profile, cost and sustainability reporting
  • Scalable for future panels, meters, generation and renewable energy

Design Principles

  • Safety first: protection, earthing, segregation, arc-risk controls, interlocks
  • Resilience: utility/generator transfer, essential distribution, UPS autonomy
  • Selective operation: coordinated protection limits the impact of a fault
  • Open integration: Modbus, BACnet, SNMP, hardwired contacts, gateways
  • Maintainability: labeling, spare capacity, accessible panels, complete as-builts
  • Energy intelligence: meters, trends, demand KPIs, scheduled reports

Distribution Hierarchy & Source-to-Load Paths

PathRoute
Normal powerUtility → RMU/MV switchgear → Transformer → MDB → SMDB → DB → final loads
Emergency powerGenerator → generator breaker/control → ATS/AMF → EMDB/ESMDB → emergency/essential SMDB/DB → priority loads
No-break powerEMDB/ESMDB → UPS input/bypass → UPS DB → critical IT, controls, medical or security loads
Renewable (optional)PV array/inverter → ACDB/protection → approved MDB connection point → building loads/grid interface
IntelligenceKWH/PQ meters, protection relays, equipment controllers → gateway/network → EMS/BMS server → dashboards, alarms, reports

Abbreviations: MDB Main Distribution Board • SMDB Sub-Main DB • ESMDB Essential Services Main DB • EMDB Emergency Main DB • DB/PDB Power DB • LDB/ELDB Lighting / Emergency Lighting DB • MCC Motor Control Center • ATS/AMF Automatic Transfer Switch / Auto Mains Failure • KWH/PQ Energy / Power-Quality Meter • UPS Uninterruptible Power Supply

Electrical Equipment & Connected Systems

EquipmentElectrical functionTypical intelligent points
Utility / grid incomerNormal source, revenue metering, service protectionAvailability, V/A/Hz/kW/kWh/PF, demand, breaker status
RMU / MV switchgearMV isolation, switching and protectionBreaker/isolator position, relay trip, earth fault
MV/LV transformerMV to LV conversion, dry or oil typeWinding temperature, fan status, trip/alarm, load
MDBMain LV board: incomers, bus sections, coupler, major feedersACB status/trip, electrical values, demand
SMDBSub-main distribution by floor, zone, tenant or plantBreaker status, energy and demand by feeder
ESMDB / EMDBEssential and emergency distribution via ATS/generatorSource and breaker status, energy, load-shed state, transfer history
DB / LDB / ELDBFinal power and lighting (normal and emergency) distributionIncomer energy, trip summary, SPD status, contactor state
MCC / VFD panelMotors for pumps, fans and HVAC plantRun, trip, local/remote, speed, current, fault code
Generator setStandby or prime emergency sourceAvailable/run/fault, electrical values, fuel, battery, coolant, oil
ATS / AMFAutomatic source selection and transferSource healthy, switch position, transfer failure, event log
Synchronizing panelOptional multi-generator or utility parallel operationSynchronization, load share, breaker and alarm status
UPS + bypassNo-break supply for IT, controls, medical loadsInput/output/bypass, battery, load %, autonomy, alarms
KWH / multifunction meterSub-metering and power-quality measurementkWh, kvarh, kW, kVA, PF, V, A, Hz, demand, harmonics
Capacitor bank / APFCAutomatic power-factor correctionPF, stage status, kvar, controller alarm
Active harmonic filterOptional harmonic mitigationTHD, compensation current, loading, alarms
Solar PV inverter + ACDBOptional distributed generation under approved protectionGeneration kWh/kW, inverter status, grid condition
Earthing & lightning protectionProtective, functional and lightning earthing, surge protectionSPD remote alarm, optional insulation monitoring
EMS/BMS server & gatewayDashboard, history, alarming, analytics, reportingModbus TCP/RTU, BACnet/IP, SNMP, API, hardwired I/O

Operating Philosophy: Emergency Sequence

1Utility fails
ATS validates loss
2Generator starts
Voltage and frequency checked
3Transfer
Emergency bus energized
4Staged restore
Critical loads first
5Utility returns
Stability delay
6Retransfer
Cool-down and stop

All events are time-stamped in the EMS/BMS where interfaces are available. Priority loads are restored in engineered steps to limit generator inrush, and non-critical feeders may be shed per the approved load-priority schedule.

Normal operation: meters record source, main bus, sub-main and major-load consumption; the EMS/BMS trends demand, power factor, balance, frequency and energy, and notifies operators of abnormal voltage, overload, breaker trip, communication loss or threshold breach.

UPS operation: supports designated no-break loads during transfer and short interruptions; static/manual bypass permits maintenance; battery autonomy is calculated from real critical load, growth allowance, technology, temperature and end-of-life capacity.

Control boundary: the EMS/BMS is supervisory. Short-circuit, earth-fault, overload, differential, reverse-power and voltage protections remain in certified relays, breakers and equipment controllers. Remote commands require approved cause-and-effect logic, access rights and interlocks.

Energy Metering Levels

  • Source: utility import/export, each generator, renewable generation
  • Main distribution: each MDB incomer, bus section, major feeder
  • Essential/emergency: ESMDB/EMDB incomers and critical feeder groups
  • Sub-distribution: SMDB by floor, department, tenant, zone or plant
  • Major loads: chillers, AHUs, pumps, lifts, data rooms, kitchens
  • Final/tenant: DB or tenant meter for billing or benchmarking

Dashboard KPIs

  • Real-time kW, kVA, kvar, PF, V, A and frequency
  • Daily/monthly/annual kWh against baseline or budget
  • Maximum demand, peak time and load factor
  • Phase imbalance, voltage deviation, harmonics
  • Utility vs generator vs renewable contribution
  • Cost and CO₂ using approved tariff and emission factors
  • Meter communication health and abnormal-consumption alarms

Integration Matrix

AssetInterfaceMonitorPermitted supervisory control*
KWH/PQ meterModbus RTU/TCPElectrical values, demand, energy, alarmsNone
MDB/SMDB breakerAux contacts / relay / gatewayOpen/closed/trip, spring, local/remoteMotorized open/close only if approved
Generator controllerModbus / BACnet / contactsAvailable, run, fault, engine dataStart-enable/reset only if approved
ATS/AMFModbus / contactsSources, position, auto/manual, eventsTest/transfer under approved procedure
UPSSNMP / Modbus / contactsInput/output, bypass, battery, load, alarmsUsually monitoring only
APFC / harmonic filterModbus / contactsPF, stages, kvar, THD, alarmEnable/reset if approved
MCC/VFDBACnet / Modbus / hardwired I/ORun, fault, speed, current, modeStart/stop/speed subject to interlocks
PV inverterModbus / vendor APIGeneration, status, alarmsCurtailment/reset if authority approved
Protection relayIEC / Modbus / gatewayTrips, measurements, event codesProtection settings excluded from BMS

* Final commands depend on the approved control philosophy, authority requirements, vendor warranty, cybersecurity review and equipment interlocks.

Network & Cybersecurity

  • Dedicated, segmented EMS/BMS network with managed switches and VLAN/firewall rules
  • Unique accounts, role-based permissions, least privilege
  • Secure remote access through client-approved VPN
  • Time synchronization, tested backups, audit logs for logins, commands and setpoint changes
  • Controller and protection operation stays autonomous during server/network interruption

Electrical Contracting Scope of Work

1Survey
Site and loads
2Design
SLD and studies
3Procure
Approved materials
4Install
Panels and cabling
5Integrate
Meters and EMS
6Commission
Tests and training
7Support
Lifecycle service
StageScorpions Services activities
Survey & verificationReview utility data, loads, existing panels, generators, earthing, routes, interfaces and site constraints
Concept & calculationsLoad schedule, maximum demand, diversity, source sizing, transformer/generator/UPS concept, metering strategy
Detailed engineeringSLD, schematics, layouts, panel and cable schedules, discrimination, short-circuit, voltage-drop and earthing calculations
ProcurementApproved switchgear, panels, meters, breakers, ATS, generator/UPS interfaces, cables, containment
InstallationPanels, cabling, busduct, trays, conduits, glands, terminations, identification, earthing, field interfaces
Programming & integrationMeter addressing, gateways, dashboards, alarms, trends, reports, event logs, user roles
Testing & commissioningInspection, electrical tests, point-to-point checks, functional sequences, transfer/load and integrated tests
HandoverAs-builts, calculations, settings, reports, O&M manuals, training, backups, warranties, spare-parts list
After-salesPreventive/corrective maintenance, emergency support, thermography coordination, firmware review, expansion

Engineering Studies & QA/QC

  • Connected-load and maximum-demand schedule
  • Short-circuit and equipment-duty verification
  • Protection coordination and settings
  • Cable ampacity, derating, voltage-drop and withstand
  • Transformer, generator and UPS sizing
  • Earthing, bonding, lightning and surge assessment
  • Arc-flash assessment where required
  • Generator step-load and load-shedding sequence
  • Metering schedule, CT ratios and communication topology

Installation Quality Controls

  • Panels plumb, accessible, ventilated, with working clearances
  • Power/control/communication segregation maintained
  • Correct glands, lugs, ferrules, torque and cable labels
  • Neutral and protective-earth conductors sized and terminated per design
  • CT polarity, ratio and shorting verified before energization
  • Fire stopping at penetrations; IP ratings maintained
  • Spare ways and bus capacity for expansion

Testing & Commissioning

TestMinimum verification
Visual / mechanicalNameplates, ratings, clearances, interlocks, torque, barriers, labels, workmanship
CablesContinuity, insulation resistance, phasing, terminations
EarthingProtective-conductor continuity and earth-system tests
SwitchgearPrimary/secondary injection, breaker operation, trip tests, settings verification
Meters / CTsPolarity, ratio, phase mapping, scaling, readings, communication
GeneratorAuto/manual start, alarms, load test, step loading, cool-down
ATS/AMFSource failure, start, transfer, retransfer, delays, interlocks, failure modes
UPSNormal, battery, bypass, alarm and autonomy/load test
EMS/BMSPoint-to-point, alarm priority, timestamps, trends, reports, user rights
Integrated testUtility outage through full emergency restoration and return to normal

Project Deliverables

  • Approved single-line diagrams, layouts, schematics, panel schedules
  • Load schedule, cable schedule, calculation package
  • Protection coordination study and settings register
  • Metering and communication architecture with address schedule
  • Panel general arrangements, wiring diagrams, bill of materials
  • Cause-and-effect, operating philosophy, load-shedding matrix
  • EMS/BMS point list, alarm matrix, trend schedule, report templates
  • Test plans and records, commissioning reports
  • As-builts, configuration backups, O&M manuals, training, warranties, spares list

Information Required

  • Project type, location, occupancy, hours, authority and standards
  • Utility supply, available fault level, tariff, service constraints
  • Architectural/MEP drawings, equipment schedules, connected loads
  • Critical, essential and non-essential load classification with restoration times
  • Generator and UPS ratings, autonomy, synchronizing and redundancy needs
  • Existing panel, cable, earthing, ATS and meter information
  • Meter granularity, cost allocation and tenant billing needs
  • Approved makes, IP rating, spare capacity, cybersecurity and reporting requirements
This page describes a system concept and typical connected equipment. It does not replace the approved electrical design, utility conditions, local authority requirements, manufacturer instructions or a site-specific risk assessment.

Discuss your project

Final ratings, quantities, fault levels and cable sizes are confirmed from the approved project design and site conditions.

Contact Us Download the PDF